    STATORICS STARTERS

    They consist in to use the perfectly studied electrolytes property that decrease its resistance as it increases its temperature by thermoelectric effect: this variation occurs in a small inter electrode chamber…

    Read more

    ROTORICS STARTERS

    It is based on the difference in resistivity that exists between a liquid electrolyte and its vapor contained in an electrode Chamber.

    The passage of the rotor initial current through the electrolyte…

    Read more

    SPEED REGULATOR

    Knowing the possibility of the rings motors to vary their motor torque depending on the resistance between phases of the circuit rotor, our company has developed a system of regulation of speed by means of liquid resistances…

    Read more

    LOW / MEDIUM VOLTAGE CAPACITORS

    In general, the electric power is defined as «the capacity of an electrical equipment to perform a work and energy the amount of work done per unit of time.

    If the installation is not properly projected…

    Read more

    SERVICES

    Study and consulting on starting projects of electric motors, the best solution, depending on the characteristics of the target facility.

    Assistance for the implementation of any starting system.

    Review of old installations, old equipments individual test and submitting a report of their condition, suggesting the maintenance or adjustment actions if deemed necessary, to improve the performance of them.

    Technical assistance, proposed improvements and / or repair of any starter fluid, regardless of manufacturer and status.

    Adaptation of old starter motors to other machines than the original.

     

    STATORICS STARTERS

    STATORICS MODELS

    • Low voltage type RZ
    • Loe voltage type RL
    • Medium voltage type RLM

    Dowload catalog PDF

    EM type starters for medium voltage ring motors

    STATORICS

    They consist in to use the perfectly studied electrolytes property that decrease its resistance as it increases its temperature by thermoelectric effect: this variation occurs in a small inter electrode chamber.

    Resistance is connected in series with the motor windings, causing a voltage drop, reducing the starting torque and also reducing the line intensity.

    As the motor speed going up will produce an automatic reduction in resistance value, thereby gradually increasing the voltage at the motor terminals providing smooth acceleration without torque shock or current spikes.

    At the start’s end a timer drives an shortcut contactor that eliminates the resistance in the circuit.

    The starting torque is adjustable depending on the electrolyte concentration (higher concentration, lower resistance and more torque) determined according to the type of machine washed or limit in the starting current

    The starter temperature controlled by a thermostat and any abnormal decrease in the level of electrolyte is detected by level control lamps.

    STATORICS STARTERS IN INSTALLATIONS

    MEDIUM VOLTAGE

    LOW VOLTAGE

    LOW VOLTAGE

    ROTORICS STARTERS

    ROTORICS FIXED ELECTRODE

    SMALL POWERS < 700 KW. :
    • Low and Medium voltage type M70
    • Low and Medium voltage type M100
    • Low and Medium voltage type M500
    MEDIUM POWERS <6.000 KW. :
    • Medium voltage type M1000
    • Medium voltage Type M2000
    • Medium voltage type M3000

    FIXED ELECTRODE.

    It is based on the difference in resistivity that exists between a liquid electrolyte and its vapor contained in an electrode Chamber.

    The passage of the rotor initial current through the electrolyte immediately produces a partial vaporization with an instant adjustment of the resistance and the start torque to optimal values.
    During the speed increase occurs an thermal Exchange that progressively condenses the vapor, which automatically decreases the resistance.

    At the end of the start period a timer activates the contactor that short-circuited rotor on the motor, eliminating the resistance in the rotor circuit.

    The starter torque is adjustable depending on the electrolyte concentration and is determined by the kind of dragged machine or current limit.
    The equipment temperature use is controlled by a thermostat.

    ROTORICS STARTERS FIXED ELECTRODE IN INSTALLATIONS

    MEDIUM VOLTAGE

    FIXED ELECTRODE

    MEDIUM VOLTAGE

    FIXED ELECTRODE

    MEDIUM VOLTAGE

    FIXED ELECTRODE

    ROTORICS MOVIL ELECTRODE

    GREAT POWERS <15 MW. :
    • Medium voltage Type EM1000
    • Medium voltage Type EM2000
    • Medium voltage Type EM3000
    • Medium voltage Type EM4000
    • Medium voltage Type EM5000
     

    Dowload catalog PDF

    EM type starters for medium voltage ring motors.

    MOVIL ELECTRODE

    To complement the range RLV, the EM-type automatic starter is designed to start slip rings motor, requiring high power or very soft starts.

    This team not only ensures a excellent start, with progressively higher speed and smoothly, but also responds to specific needs, such as speed control slip rings motor and counter-current braking.

    Its principle is introduced into the rotor circuit a variable electrolytic resistance through three movable electrodes, which progressively reduced the distance between phases and neutral, and with her resistance, yet this set immersed in an electrolyte at a constant level.

    That is whay you can get a wide range of resistance variation ( up 1: 100) by the displacement of the electrodes inside the electrolyte.
    At the start end the resistance is removed by a short-circuited contactor.

    ROTORICS STARTERS MOVIL ELECTRODE IN INSTALLATIONS

    MEDIUM VOLTAGE

    MOVIL ELECTRODE

    MEDIUM VOLTAGE

    MOVIL ELECTRODE

    MEDIUM VOLTAGE

    MOVIL ELECTRODE

    SPEED REGULATOR FOR RING MOTORS

    Knowing the possibility of the rings motors to vary their motor torque depending on the resistance between phases of the circuit rotor, our company has developed a system of regulation of speed by means of liquid resistances that they provide the following possibilities.

    • Very smooth rise from 0 to the speed consigned

    • Technically simple and very robust system.

    • Very stable easy to adjust, both in manual and automatic mode.

    • Closed-circuit electrolyte refrigeration with plate heat exchanger.

    • Recirculating the electrolyte by means of a standard high-flow pump and low consumption.

    • Automatic ON/OFF Control of the cooling system by means of a double-set thermostat.

    • IP55 Control Panel for system-wide automation.

    • Economical solution with short delivery times, low maintenance and correct operation guarantee.

    SPEED REGULATOR FOR RING MOTORS IN INSTALLATIONS

    VARIATOR 4.000 KW

    VARIATOR 4.000 KW

     

    VARIATOR 2.000 KW

     

    GENERAL TECHNICAL CHARACTERISTICS

    Soft start, progressive and smoothly in all types of electric slips rings or cage motors, with unlimited power and load in any situation.
    Possibility to adjust the resistance to get an exact value for the desired STARTING TORQUE, limiting the maximum current intensity absorbed.
    Possibility to adapt the starter to other motors or machines with completely different characteristics to the initials.
    The thermal variables resistance can not be burned never because to be liquid.
    Virtually no maintenance.
    Warranty and total absence of fault attributable to the system.
    Only need 3 sections of wire from the box to the motor.
    Those starters allow you to start a cage motors, either at 220 or 380 volts, not having to make the transition from star to delta.
    Very compact, robust and ready to work in the most adverse conditions, including weather and dusty atmospheres, corrosive or wet environments.
    Price performance ratio very interesting.
    Because we assemble standard modular elements, delivery times can be very short.

    LOW / MEDIUM VOLTAGE CAPACITORS

    Dowload catalog PDF

    Technical documentation capacitors

    In general, the electric power is defined as «the capacity of an electrical equipment to perform a work and energy the amount of work done per unit of time.

    If the installation is not properly projected, important losses can occur with the generation of reactive energy.

    In our company we specialize in the correction of the power factor and we offer solutions adapted to each segment of the market. We know how to identify the needs of each client, and we personalize our service to detail, keeping ourselves faithful to our commitment to innovation and quality.

    CAPACITORS AND BANKS

    LOW AND MEDIUM VOLTAGE (LV – MV)

    MV Capacitor are constituted by elementary units, consisting of aluminum foil windings of high purity and polypropylene film of the highest quality.

    HARMONIC FILTERS

    Three phase harmonic filters are made of low losses magnetic, copper conductor and 90, 120, 140 and 160ºC thermal protection relay. Standard surge factor is 7% and 14% with 189 and 134 Hz for 50 Hz and 227 – 161 Hz. networks.

    RESOLVE ANY PROBLEM IN REACTIVE ENERGY THAT YOU COMMUNICATE

    LOW / MEDIUM VOLTAGE CAPACITORS IN INSTALLATIONS

    CAPACITORS

    HARMONICS FILTERS

    BANKS COMPENSATION

    REACTIVE ENERGY

    COMPANY

    ABOUT OUR COMPANY

    TEMIC SCP., is a specialized company in starter systems using liquid resistance for medium and high power induction electric motors.

    Company created in 1982, however this very specialized activity came from the evolution, development and research conducted in other related companies that with the passage of time led to the union of human and technical elements, which with the trust of our customers gave way to the creation of this extraordinarily specialized company in the starter of electric motors and derived applications. For this reason it is easy to find on the market with our know how built more than 40 years ago.

    WHAT DO WE DO?

    Our start system is based in to use the perfectly studied property of the electrolyte, which decreases their resistance as it increases its temperature by thermoelectric effect.

    This variation is generated in a small electrode chamber is and produced by the same intensity when pass through the electrolyte.

    Our production is divided into two large groups RED stator starters : type for a cage Motors, and RLV or EM rotor starters type for a sleep rings motors. In this group we can find the starters with fixed electrodes (RLV) and mobile electrodes starters (EM).

    CONTACT

    TEMIC SCP.

    C/ Carrasco i Formiguera, 36
    08191 RUBI (BARCELONA)
    ESPAÑA

    Telf.  (34) 93 699 81 61

    Fax. (34) 93 697 31 30

    E-mail. temic@temycsa.com

    CONTACT FORM

    OUR CLIENTS